5.0 |
Antistatic and Electrically Conductive Hoses |
|
Static charge and EX protection – no problem.When solid and liquid materials are conveyed through chargeable tubes or hoses, electro-static charging (separation of charged particles) occurs due to the friction of the material against the wall and the friction within the medium. The primary hazards are: …
| ||
| NORRES Schlauchtechnik /
Industrial Hoses
/
Products
/ 5 Antistatic and Electrically Conductive Hoses | ||
| 5.1.0 | AIRDUC® PUR 351 EL |
|
| -40°C to +90°C PUR <10³ Ω, light, smooth interior, robust and abrasion-proof, capable of electro-static discharge | ||
| 5.1.5 | AIRDUC® PUR 351 ExTra |
|
|
| ||
| 5.2.0 | AIRDUC® PUR 355 EL |
|
| -40°C to +90°C PUR <10³ Ω, heavy, smooth interior, robust and abrasion-proof, capable of electro-static discharge | ||
| 5.2.5 | AIRDUC® PUR 355 ExTra |
|
|
| ||
| 5.3.0 | AIRDUC® PUR 356 EL |
|
| -40°C to +90°C PUR <10³ Ω, super-heavy, smooth interior, robust and abrasion-proof, capable of electro-static discharge | ||
| 5.4.0 | PROTAPE® PE 322 EL |
|
| -35 °C to +80 °C PE <10³ Ω, super-light and compressible, highly chemical resistant, capable of electro-static discharge | ||
| 5.5.0 | AIRDUC® PE 362 EL |
|
| -35 °C to +80 °C PE <10³ Ω, medium-heavy, smooth interior, highly chemical resistant, capable of electro-static discharge | ||
| 5.7.0 | EVA 373 AS |
|
| -25 °C to +65 °C EVA < 10¹¹ Ω, light, crush-proof, light-weight | ||
| 5.8.0 | CP PTFE/HYPALON®-VA 472 EL |
|
| -40 °C to +170 ºC TEFLON® < 10⁶ Ω super-light and compressible, highly chemical resistant, capable of electro-static discharge (to +170 °C) | ||
| 5.9.0 | CP VITON® 459 EL |
|
| -20 °C to +210 °C VITON® < 10⁴ Ω, super-light and compressible, Ø to 1,000 mm, capable of electro-static discharge (to +210 °C) | ||
| 5.10.0 | CP PTFE/Glas-VA 471 EL |
|
| -150 °C to +250 ºC TEFLON® < 10⁶ Ω super-light and compressible, highly chemical resistant, capable of electro-static discharge (to +250 °C) | ||
| NORRES Schlauchtechnik /
Industrial Hoses
/
Products
/ 5 Antistatic and Electrically Conductive Hoses | ||
Static charge and EX protection – no problem.When solid and liquid materials are conveyed through chargeable tubes or hoses, electro-static charging (separation of charged particles) occurs due to the friction of the material against the wall and the friction within the medium. The primary hazards are:
The evaluation of the particular application and the choice of protective measures to be taken can only be made by the person responsible for design engineering and operation. Here are the most important domestic and international regulations:
Engineering modifications subject to change. |
![]() ![]()
| |
| ||
| NORRES Schlauchtechnik /
Industrial Hoses
/
Products
/ 5 Antistatic and Electrically Conductive Hoses | ||